<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Geomatics Science and Technology</title>
<title_fa>علوم و فنون نقشه برداری</title_fa>
<short_title>JGST</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://jgst.issgeac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2322-102X</journal_id_issn>
<journal_id_issn_online></journal_id_issn_online>
<journal_id_pii>-</journal_id_pii>
<journal_id_doi>10.66224/jgst</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>-</journal_id_sid>
<journal_id_nlai>-</journal_id_nlai>
<journal_id_science>-</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1405</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2026</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>توسعه رویکردی سه‌مرحله‌ای برای تشخیص و بازیابی اتوماتیک تست فیلد صفحه‌ای در کالیبراسیون دوربین-پروژکتور زاویه باز</title_fa>
	<title>A Three-Stage Automatic Detection and Retrieval Process for Field-Testing Pages for Calibrating a Wide-Angle Camera-Projector</title>
	<subject_fa>فتوگرامتری و سنجش از دور</subject_fa>
	<subject>Photo&amp;RS</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family:IRANsharp;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;&lt;span style=&quot;letter-spacing:-0.1pt&quot;&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;کالیبراسیون دوربین&#8204;های غیر متریک عموما توسط یک تست فیلد صفحه&#8204;ای انجام می شود. در این تحقیق با هدف کالیبراسیون یک سامانه استریوی دوربین-پروژکتور یک تست فیلد صفحه ای طراحی شده است که امکان بازیابی فاز مرکز هر کدام از تارگت&#8204;ها با بالاترین دقت ممکن فراهم باشد. این تست فیلد از تعدادی تارگت دایره ای سفیدرنگ در زمینه سیاه تشکیل شده&#8204;است که بر روی یک صفحه چاپ شده&#8204;است. سه تارگت حلقوی شکل با آرایش مثلث قائم الزاویه در مرکز تست فیلد یک وضعیت منحصر بفرد ایجاد می&#8204;کند که برای کددهی تارگت&#8204;های تست فیلد قرار داده شده&#8204;است. وجود اعوجاج شعاعی در دوربین زاویه بازی که در این تحقیق استفاده شده&#8204;است، کددهی تارگت&#8204;های حاشیه تست فیلد را با چالش جدی مواجه ساخت. برای حل آن از سه تبدیل هندسی افاین، پروژکتیو و چندجمله&#8204;ای دو بعدی به طور متوالی بهره گرفته شد&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt; که توانست از عهده اعوجاجات شعاعی شدید برآید&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;. خطای بازیابی مختصات مرکز تارگت&#8204;ها در بالاترین زاویه دوران تست فیلد و بالاترین اعوجاج شعاعی &lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt;ممکن به میزان &lt;/span&gt;&lt;/span&gt;0.2&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt; پیکسل برآورد شد. پس از کالیبراسیون دوربین توسط تست فیلد پیشنهادی خطای &lt;/span&gt;&lt;/span&gt;RMSE&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt; کالیبراسیون برای دوربین فوجی فیلم، &lt;/span&gt;&lt;/span&gt;0.09&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt; پیکسل &amp;nbsp;پیکسل و برای دوربین گوپرو، &lt;/span&gt;&lt;/span&gt;0.07&lt;span lang=&quot;FA&quot;&gt;&lt;span b=&quot;&quot; nazanin=&quot;&quot;&gt; پیکسل برآورد گردید.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;
&lt;br&gt;
&amp;nbsp;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:12px;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span new=&quot;&quot; roman=&quot;&quot; times=&quot;&quot;&gt;Non-metric camera calibration is commonly performed using a planar calibration test field. In this study, a novel planar test field was designed for the calibration of a stereo camera&amp;ndash;projector system, with the objective of enabling highly accurate phase recovery at the center of each target. The proposed test field consists of an array of white circular targets printed on a black background. Three concentric ring-shaped targets, arranged in a right-triangle configuration at the center of the test field, provide a unique reference pattern for automatic target identification and coding. However, the severe radial distortion introduced by the wide-angle camera used in this study posed a significant challenge for the correct identification of targets located near the image boundaries. To address this issue, three geometric transformations&amp;mdash;affine, projective, and two-dimensional polynomial transformations&amp;mdash;were applied sequentially, enabling reliable compensation for severe radial distortion. Experimental results showed that, even under the maximum test-field rotation angle and the strongest simulated radial distortion, the target center localization error did not exceed &lt;strong data-end=&quot;1379&quot; data-start=&quot;1365&quot;&gt;0.2 pixels&lt;/strong&gt;. Furthermore, camera calibration using the proposed test field achieved root mean square errors (RMSEs) of &lt;strong data-end=&quot;1502&quot; data-start=&quot;1487&quot;&gt;0.09 pixels&lt;/strong&gt; for the &lt;strong data-end=&quot;1523&quot; data-start=&quot;1511&quot;&gt;Fujifilm&lt;/strong&gt; camera and &lt;strong data-end=&quot;1550&quot; data-start=&quot;1535&quot;&gt;0.07 pixels&lt;/strong&gt; for the &lt;strong data-end=&quot;1568&quot; data-start=&quot;1559&quot;&gt;GoPro&lt;/strong&gt; camera, demonstrating the high accuracy and robustness of the proposed calibration approach.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>تست فیلد صفحه ای, تبدیل پروژکتیو, اعوجاج شعاعی, کالیبراسیون دوربین, کددهی تارگت</keyword_fa>
	<keyword>planar test-field, projective transformation, radial distortion, camera calibration, target encoding.</keyword>
	<start_page>1</start_page>
	<end_page>16</end_page>
	<web_url>http://jgst.issgeac.ir/browse.php?a_code=A-10-643-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>ali</first_name>
	<middle_name></middle_name>
	<last_name>abzal</last_name>
	<suffix></suffix>
	<first_name_fa>علی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابذل</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ali.abzal14@gmail.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه اصفهان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
